You should be able to press the start/stop button to start up the pump. I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. Pool Heat Pump Repair | Pool Heater Repair, Energy Saving Tips For Your Swimming Pool, Measure water temperature with a thermometer to rule out a faulty temperature sensor, Hire professional pool heat pump repair tech to inspect control board, thermistor, andunit, See HIGH WATER TEMP troubleshooting steps, Check that pool pump is sending water to heater, Ensure that pool pump is receiving enough water, Check that your pool systems multiport valves are on the correct settings, Have pool heater repair tech check for bad pressure switch (or check it yourself), Seek pool heater repair tech to troubleshoot the water thermistor, Seek pool heater repair tech to troubleshoot the defrost thermistor, Check that transformer supply voltage is within 208 260 volts, Check that transformer outputis between 24 28 volts, Replace transformer is voltage is below those ranges, Check that heat pump supply voltage is between 208 -260 volts, Ensure that pool pump is sending water to your pool heater, Check for any blockage in baskets and filters that are affecting water flow, Have pool heater tech inspect higher-pressure switch, The unit may have a refrigerant leak. 0F Absolute AC Under-Voltage Detected: This indicates that the supply voltage has dropped below the operating range of 99v. It will then begin to go into the priming mode and then start up. Looking at the case of the drive (where the ground screw attaches) you will notice that the seating surface for the ground wire is covered in powder coating. A Pentair IntelliFlo 2 VST. A repository of Pentair stakeholder and customer information at your fingertips including white papers, case studies and product manuals, etc. Followed instructions on page 14 of manual. You should be able to press the start/stop button to start up the pump. You would think the ground screw would be conductive enough but it turns out that green coating has a ton of resistance and prevents you from getting a good ground.So I carefully removed the powder coating under that ground screw and reconnected everything and my resistance went to 0 ohm on the ground line indicating a perfect path to ground. I originally. So, if you have an older pool Went out to check on the pool before work and Monday and noticed that the pump was not running. Also make sure both the skimmer and pump basket do not have rips or tears which could allow debris to get through and into the pump impeller. There is either a white or yellow wire connected directly to the back of the board. It means that your heater is getting too hot and the high limit switch turns off the heater for safety. The freon in your pool heating system should last roughly 15 years, or as long as the device itself. To prevent the impeller from being clogged check your skimmer clear the impeller jam the pump will start up and run like normal. Read our troubleshooting guide to figure out how to fix a faulty Pentair blower. All Right Reserved by HeaterFixLab. Hello , This is an inactive thread. If necessary, clean the heat exchanger. Pentair pool heater troubleshooting guide, Pentair Heater Error Codes [Reasons + Solutions], Water Flow Rates For Different Pentair Models, 2 More Confused Error Codes Of Pentair Heater. My family and friends were all swimming this past weekend with no issues. WARNING: Any troubleshooting that involves electrical work is dangerous, and should be performed by a professional pool heater repair tech. If your mini-split has a leak, a professional may be required to add refrigerant after the repairs are completed. I installed a new Superflo VS pump on my 16x36 inground pool. Simply open the front door and look directly behind the control board. choice for a Variable Speed Pump. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. If it is connected at the skimmer you may want to try the after-market Hole in One Basket for the skimmer. E01/E126 Error Code 8. Are you checking the pump voltage when it is running? its quick and easy way. Unable to clear error message and restart. Gently turn it back in forth until the You can turn the impeller by using a 1/4 allen wrench at the back in the fan. If Code ERR is shown on the LED display at any time, turn the heater off at the power switch and then turn the heater back on. 21 Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. Regular Unscented Bleach I started doing pool service when I was 16 years old back in 1988. I have same code. It may not display this or other websites correctly. Our expert will help you ASAP. The thermal fuse is usually sealed with wax. It is being practiced by thousands of pool owners just like you. The Pentair SuperFlo Variable Speed pump is a great This means the motor was getting too hot. Try cleaning it up if the water flow is less than ideal. Learn more Shop Now Pentair - EC-011059 - IntelliFlo i1 Variable Speed Pool Pump - Limited Warranty $1,859.00 Error Code E06: Stack Flue Sensor Is Shorted 3. will no longer show the Err 0002 code. It will stay off until the filter pump timer is reset, providing the heat pump with the necessary water flow. great performance. The second method is to use a Allen Wrench and I set up a gopro for hours and finally caught it giving and error 0021.Pentair was an absolute disaster to deal with but i was finally able to get them to send me a new drive. Check to make sure the wire supplying . If you have any questions regarding Pentair gas pool heater error codes, you can leave us a comment. I tried hard resetting and turning off power for multiple minutes. ERR SFS Error Code 7. Error Code R13: Startup Mode 4. insert it into the back of the pump. filter sock or filter saver in the skimmer basket to trap the smaller particle Create an account to follow your favorite communities and start taking part in conversations. So when the E03 error code comes up, you can conclude that your heater is burning. Pentair heat pump error code LOW WATER FLOW LOW WATER FLOW What it means: the unit's low-pressure switch senses that water flow is open or low How to fix it: Check that pool pump is sending water to heater Ensure that pool pump is receiving enough water Check that your pool system's multiport valves are on the correct settings Variable speed pumps move water more efficiently at lower speeds, saving money and energy. pump was working now just blinks yellow wont start any suggestions ?? This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply. The method I always use is Be sure to contact us through our website for our variety of services.. You will get much more visibility by. Let me know what you find. I looked down and viewed my mistake of allowing part of the plastic sheet to cover the pool motor fan intake. if you have problem to your pool pump pentair. *17,16, 02, 08, 04, 06, 09, 0A Internal Errors: These errors can occur based on operating conditions and the UL 60730 required self-diagnostic safety software. Spin it Replacement drive did the same thing so i started doing some basic troubleshooting and i think i figured out the cause. If you have a suction side cleaner connected to the pool, make sure you are using an in-line leaf canister. Is that an overcurrent fault code? Otherwise, the temperature sensor may be faulty. (The fan and impeller are on the same axle.) Who Makes the Best Pool Equipment -Pentair, Hayward, Jandy or Off Brands? These codes arent an indication of an error but users get confused as to what they mean. The most common one is the Err 0002 and it is usually caused by the impeller getting clogged and the pump is unable to prime. Troubleshoot the high-pressure issue causing the error. It would self prime in about 1 minute and everything was happy. I figure after looking at this dissassembled you could tell if it was impeded by some cruft in the impeller by trying to turn it manually. Doing this may free the blockage. : https://www.swimmingpoollearning.com/swimming-pool-care-ebook, https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzP, Swimming Pool Tips, Reviews & How To Video Index (List) Alphabetical order. Benefits of a Pentair Variable Speed Pool Pump Higher Performance Consistent flow control for the highest energy saving and ultimate system performance. What would be the cause of that? I've had an occasional bad drive out of the box. You are using an out of date browser. Go Back. It is very reliable and will give you years of How to Fix an Err 0002 on a Pentair SuperFlo Vs Pump. It is probably a built-in Error Code ERR PS: Water Pressure Switch Is Open 7. POOL OPERATORS AND OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS IN THE OWNER'S MANUAL BEFORE USING THIS PUMP. I'm guessing water is still frozen causing this? They mean the same. Maybe thats why you initially mistook it for an error code. Save the speed you have chosen by pressing and holding the speed buttons to allocate that speed. cleared. The ERR HLS code means that your heaters high-limit switch is stuck open. The screen will display an error code as Err and then display a number. All rights reserved. Error Code AD0: Bad Keypad 6. When the pump is running it seems to run for 20 - 30 minutes then it cuts off for 15 - 20 seconds then comes back on. 02 -Absolute Phase current limit exceeded*, 08 -Absolute Diode Bridge temperature limit exceeded*, 04 -Absolute Power Module temperature limit exceeded*, 06 -Absolute Power Factor Correction (PFC) temperature limit exceeded*. Press question mark to learn the rest of the keyboard shortcuts. internal slip and 2 in. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. Any new postings here are unlikely to be seen or responded to by other members. If you have a suction side cleaner Any comments on this would be great. Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. Note: The IntelliFlo's internal anti-freeze protection is disabled when connected to an IntelliTouch system. What exactly should I be looking for? The FLO code indicates that the water flow to your heat pump has been halted by the filter pump. There are a number of reasons why your blower can stop working. The method I always use is to remove the pump lid and pump basket, then I spin the impeller with a screwdriver. Hi, I installed a brand new pump. The Pentair heater error codes displayed in your heater display tell you that you need to address specific issues with your heater. Using an extension cord or wiring to outlet is too light. The manual states that I should disassemble the pump and check the impeller and seal plate. Press your desired speed button (from 1 to 4) for about 3 seconds to choose the preset pump speed to reset the speed. read more Poolservice123 CPO, CPI, CBP Associate Degree 1,028 satisfied customers I have a Pentair SuperFlo VST pump motor that I need to A malfunctioning ignitor, a busted control module, a clogged or damaged flame sensor, a bad thermal regulator, or defective AGS or AFS are the likely reasons. Thanks --Jason The manual states that I should disassemble the pump and check the impeller and seal plate. If you had an installer do it, and you still have a warranty, i would call them out (because it is free) and tell them about this repair and see what they say. Pentair Pool Pump Not Working? What could be the issue here? I happened to have a deep socket. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. You must log in or register to reply here. RESOLUTION Deactivate then reactivate power to the heat pumpto clear error. And does anyone have a possible idea as to what is happeneing? It is being practiced by thousands of pool owners just like you. Ran fine all summer. Pool Pumps Inground Pool Pumps With the wide selection of inground pool pumps from Pentair, your perfect pool pump is waiting for you.
Age Limit For Jury Duty In California, Articles P